--- Ethernet Interface ---
$ chdev -dev ent0 -attr jumbo_frames=yes
$ chdev -l en0 -a mtu=9000
> vios 및 etherchannel 구성전에 적용할 것!!!
--- vSCSI Interface ---
$ chdev -dev fscsi0 -attr fc_err_recov=fast_fail dyntrk=yes -perm
$ chdev -dev hdisk1 -attr reserve_policy=no_reserve
$ chdev -dev hdisk1 -attr algorithm=round_robin
$ chdev -l hdisk1 -a hcheck_interval=60 -P
# chdev -l vscsi0 -a vscsi_err_recov=fast_fail
# lsdev –Cc adapter | grep fcs | grep –v grep | awk '{print "chdev –l " $1 " –a num_cmd_elems=2048 –P " }' | sh -x
# lsdev –Cc disk | grep –v hdisk0 | grep –v hdisk1 | awk '{print "chdev –l " $1 " –a queue_depth=20 -P" }' | sh -x
# lsattr -El hdisk2 | grep "hcheck_"
# lspv | awk '{print "chdev -l " $1 " -a hcheck_interval=60 -P " }' | sh -x
--- NPIV Interface ---
# chdev -l vscsi0 -a vscsi_err_recov=fast_fail
# chdev -l vscsi0 -a dyntrk=yes
# lsdev –Cc adapter | grep fcs | grep –v grep | awk '{print "chdev –l " $1 " –a num_cmd_elems=2048 –P " }' | sh -x
# lsdev –Cc disk | grep –v hdisk0 | grep –v hdisk1 | awk '{print "chdev –l " $1 " –a queue_depth=20 -P" }' | sh -x
--- vios server 10g adapter ---
-> vios 10g adapter
# chdev -l ent0 -a large_send=yes
# chdev -l ent0 -a large_receive=yes
-> vios server SEA
# chdev -l ent8 -a largesend=1
# chdev -l ent8 -a large_receive=yes
-> vios vlan adapter
# chdev -l ent2 -a min_buf_medium=512 -a max_buf_medium=1024 -a min_buf_large=96 -a max_buf_large=256 -a min_buf_huge=96 -a max_buf_huge=128 -P
--- vios client ---
-> virtual ethernet adapter
# ifconfig en0 largesend
-> /etc/inittab 에도 추가하여 재부팅시마다 largesend가 적용되도록 할 것
# chdev -l ent0 -a min_buf_medium=512 -a max_buf_medium=1024 -a min_buf_large=96 -a max_buf_large=256 -a min_buf_huge=96 -a max_buf_huge=128 –P
--- lpar 10g adapter ---
# chdev -l ent0 -a large_send=yes
# chdev -l ent0 -a large_receive=yes
--- processor affinity ---
# lssrad -av
--- others ---
# virtual apdatper에서 entstat -d ent0 혹은 netstat -v ent1로 볼때 Packets Dropped / No Resource Error / Hpervisor Failure 오류가 발생하는 경우
-> chdev -l ent1 -a min_buf_medium=512 -a max_buf_medium=1024 -a min_buf_large=96 -a max_buf_large=256 -a min_buf_huge=96 -a max_buf_huge=128 -P
'IBM Power' 카테고리의 다른 글
ASO (Active System Optimizer) movie - Nigel Griffiths (0) | 2013.10.29 |
---|---|
mkssys로 aix에서 service 등록하고 운영하기 (0) | 2013.07.16 |
Tips for implementing NPIV on IBM Power Systems (0) | 2013.07.10 |
PowerVM NPIV / IBM Switch Configuration (Technote) (0) | 2013.07.10 |